CARTA Classic — Over/Under Heating
If your CARTA Classic is not reaching the set temperature, overshooting it, or producing inconsistent heat, the most common fix is recalibrating the atomizer. The CARTA Classic requires a manual recalibration process (unlike newer devices).
Troubleshooting steps
- 1Update firmware
Connect the device to the V Browser app (www.focusv.app) and install any available firmware updates. Firmware updates can resolve heating inaccuracies caused by software bugs.
- 2Let the device reach room temperature
Use an external thermometer to verify the device is as close to 77°F (25°C) as possible before calibrating. Calibrating at the wrong ambient temperature will produce inaccurate results.
- 3Enter calibration mode
Press the power button 4 times consecutively. On the 4th press, hold the button until you observe the reset/calibration sequence. Release once the LED pattern confirms calibration mode.
- 4Verify temperature after calibration
Fire the device and allow it to complete a full heat cycle. Use the external thermometer to confirm the actual temperature matches the set preset. If off, repeat the calibration.
- 5Register and submit warranty claim if unresolved
If heating issues persist after calibration, register your product at focusv.com/apps/product-registration and submit a support request at portal.focusv.com.