AERIS — How to Clean
Clean your AERIS every 25–50 sessions to maintain flavor, prevent error codes, and extend device life. You'll need: 70–90% isopropyl alcohol, cotton swabs, paper towels, and a small soaking container.
Atomizer cleaning
- 1Power off and cool down
Click the V button 5 times to power off. Wait until the atomizer is cool and safe to touch — at least 2 minutes after the last session.
- 2Remove the atomizer
Grip the lower cylinder and turn counterclockwise to unscrew. If it feels stuck, run a 15-second session at the lowest temperature (Blue preset) to loosen residue, then power off and cool before removing.
- 3Remove silicone accessories
Take off the silicone bumper and carb cap tether. These should not be submerged with the atomizer.
- 4Soak in isopropyl
Place the atomizer in a container with 70–90% isopropyl alcohol. Soak for 10 minutes. Give it a shake halfway through.
- 5Clean connection points
After soaking, use an isopropyl-dampened swab to clean the atomizer's connection pins, removing any remaining residue.
- 6Dry completely
Pat dry with a paper towel. Air dry for at least 1 hour (2 hours is ideal). Do not reinstall or use while any moisture remains.
- 7Reinstall
Thread the dry atomizer back in clockwise until snug. Run a 15-second test session at the lowest temperature to confirm proper operation.
Mouthpiece cleaning
- 1Remove the silicone mouthpiece
Grip the silicone mouthpiece and pull it straight off the AERIS body. It detaches magnetically and comes off as a single unit with the ceramic insert inside.
- 2Push out the ceramic insert
Hold the silicone mouthpiece with the mouth opening facing you. Place both thumbs on the mouth end and push firmly inward. The ceramic insert pops out the other end.
- 3Clean the ceramic insert
Soak the ceramic in 70% isopropyl alcohol for 10 minutes, then rinse with warm water. Pat dry and allow to air dry fully before reinstalling.
- 4Clean the silicone mouthpiece
Rinse the silicone under warm water. Use a cotton swab dampened with isopropyl to clean the interior air pathway. Allow to dry completely.
- 5Reinstall the ceramic
Align the ceramic with the keys inside the silicone and press firmly back in with both thumbs from the mouth end until it seats flush.
- 6Reattach to the AERIS
Press the silicone mouthpiece back onto the AERIS body. The magnet will pull it into place.
Cleaning frequency
- After every session — Swab atomizer cup with a dry swab while warm
- Every 25–50 sessions — Full atomizer soak and base port cleaning
- Every 25–50 sessions — Mouthpiece soak and pathway cleaning
Related articles
Was this article helpful?
Still need help?
Our support team is here for you. Submit a ticket and we'll get back to you within 1–2 business days.
Submit a ticket